NFA11版本升级到12版本

NFA11版本升级到12版本

Please refer the upgrade steps:

Instructions to apply the Upgrade Pack
  • Shutdown the OpManager service.
  • IMPORTANT: Take a copy of the entire <NetFlow> installation directory or VM Snapshot as backup and save it somewhere before applying the upgrade pack. In addition, if you are using MS SQL server as the backend database, take backup of OpManager database (DB name 'netflow').
  • Open Task Manager and kill any process like java.exe, postgres and  OpManagerTrayIcon, NetFlowAnalyzerTrayIcon, NetworkConfigurationManagerTrayIcon, OpUtilsTrayIcon or FirewallAnalyzerTrayIcon if running and the proceed with the upgrade process.
  • Rename the folder named logs as logs_old under NetFlow_Home directory.
  • Open command prompt as Administrator (Right click on CMD -> Run As Administrator) and navigate to < NetFlow_HOME>/troubleshooting and execute rawCleanup.bat and wait for it to complete.
  • Navigate to < NetFlow_HOME>/bin (in CMD as Administrator) directory and execute UpdateManager.bat or sh UpdateManager.sh (Linux).
  • Click Browse and select the .ppm file that you have downloaded from the above link.
  • Click Install to install the upgrade pack. Wait until the upgrade pack is fully installed. [Normally, it takes a few minutes for PPM installation].
  • Click Close and then click Exit to exit the Update Manager tool.
Important (must follow)
  • Once done navigate to NetFlow_Home\bin in CMD and execute run.bat (Windows) or run.sh (linux), check if application starts properly. If yes please hit CTRL+C and proceed with the next upgrade.
  • Finally start the OpManager service.
    • Related Articles

    • OPM下如何查看tomcat版本?

      解压OpManager\lib\tomcat目录下的catalina.jar    打开META-INF文件夹下的 MANIFEST.MF文件,找到'Implementation-Version' 显示 tomcat 版本。
    • 在尝试监控JBoss时,我没有获得JVM和EJB详细信息,同时在顶部出现一条消息“选择JBoss版本。编辑监视器从而更改版本。”

      原因: JBoss在Applications Manager中自动被发现。但是JBoss实例的版本没有更新。 解决方案: 要获取JVM、JDBC和EJB详细信息,请点击“配置”选项并输入JBoss服务器的版本(3.2.x、4.x)。
    • 将OpManager升级到最新版本

      问题:如何将OpManager升级到最新版本。 解决方案: 根据当前版本,选择以下升级路径。 8000/8721/8723/8800                                            ->> 8810                              8810/8811/8812/9000                                            ->> 9010                                ...
    • APM数据收集需要Powershell版本4或更高版本

      低于powershell版本4不支持Applications Manager用于数据收集的某些cmdlet。 例如用于端点连接检查的“Test-NetConnection”cmdlet在旧版本powershell中不可用。 请升级到更高版本的Powershell来查看丢失的数据。
    • 将OpManager DB从PGSQL迁移到版本125230中的MSSQL

      对于OpManager版本125230: PGSQL到MSSQL的迁移步骤: 在PGSQL设置中,转到OpManager主页 → bin,从此路径以管理员权限启动命令提示符,然后运行DBConfiguration.bat。 在显示的弹出窗口中,请选择MSSQL,选中“从现有数据库迁移数据”选项,然后点击确定。 迁移完成后,启动产品并检查其是否正常运行 从MSSQL到PGSQL的迁移(适用于预填充和非预填充设置): 1. ...